Rapid Manufacturing Ventilator

Abstract

The reports of the ventilator shortage in Italy inspired many teams worldwide to attempt designing easily manufacturable ventilators utilizing several different approaches. However, it was challenging to comply with the international standards for critical care ventilators and to provide ventilator parameter setting compliant with the current protective ventilation recommendations according to the latest evidence-based medicine. The properties of the ventilator evaluated during its first use on a patient on October 31, 2020, proved its applicability in the clinical practice, the accuracy of ventilator parameters and the ability to easily switch between Coro Vent and a standard mechanical lung ventilator. The Coro Vent project demonstrated that even a rapidly manufactured ventilator can help to manage pandemic situations if it is developed in accordance with the international technical standards for critical care ventilators.

Country : India

1 Shweta Kanakdande2 Anushka Isane3 Pawan Sagade4 Prof. Dr. S.B.Dhonde

  1. Student, B.E., Electronics and Telecommunication, AISSMS Institute of Information Technology, Pune, Maharashtra, India
  2. Student, B.E., Electronics and Telecommunication, AISSMS Institute of Information Technology, Pune, Maharashtra, India
  3. Student, B.E., Electronics and Telecommunication, AISSMS Institute of Information Technology, Pune, Maharashtra, India
  4. Professor, B.E., Electronics and Telecommunication, AISSMS Institute of Information Technology, Pune, Maharashtra, India

IRJIET, Volume 6, Issue 8, August 2022 pp. 151-153

doi.org/10.47001/IRJIET/2022.608022

References

  1. https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/86167/RMVS001_v3.1.pdf. Accessed 15 Apr 2020.
  2. https://www.medscape.com/answers/81012645486/what-is-the-normal-inspiration-and-expirationratio-in-mechanical-ventilation. Accessed 18 May 2020.
  3. https://www.mohfw.gov.in/pdf/EssentialTechfeaturesforVentilators.pdf. Accessed 18 May 2020.
  4. Aït-Khaled N, Enarson D, Bousquet J. Chronic respiratory diseases in developing countries: the burden and strategies for prevention and management. Bull World Health Organ. 2001; 79(10):971:979. [PMCfree article]  [PubMed]  [Google Scholar]
  5. Al Husseini AM, Lee HJ, Negrete J, Powelson S, Servi A, Slocum A, Saukkonen J (2010) Design and prototyping of a low-cost portable mechanical ventilator. In: Proceedings of the 2010 design of medical devices conference, DMD2010 April 13–15, Minneapolis, MN, USA.  https://web.mit.edu/2.75/projects/DMD_2010_Al_Husseini.pdf [PMC free article]  [PubMed]
  6. Bachiller PR, McDonough JM, Feldman JM. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Anesth Analg. 2008; 106(5):1392–1400. doi: 10.1213/ane.0b013e31816a68c6. [PubMed] [CrossRef] [Google Scholar]
  7. Cao X. COVID-19: immunopathology and its implications for therapy. Nat Rev. 2020; 20: 269–270. [PMC free article] [PubMed] [Google Scholar]
  8. Darwood A, McCanny J, Kwasnicki R, Martin B, Jones P. The design and evaluation of a novel low-cost portable ventilator.  Anaesthesia.  2019; 74: 1406–1415. doi: 10.1111/anae.14726.  [Pub Med]  [CrossRef] [Google Scholar]
  9. Hedenberg H. U.S. Patent No. 6,263,873. Washington, DC: U.S. Patent and Trademark Office; 2001. [Google Scholar]
  10. Hess DR, Kacmarek RM. Essentials of mechanical ventilation. 3. USA: McGraw-Hill Education/Medical; 2014. [Google Scholar]
  11. Jain RK, Swaminathan S. Anaesthesia ventilators. Indian J Anaesth. 2013;57(5):525. doi: 10.4103/0019-5049.120150. [PMC free article]  [Pub Med] [CrossRef] [Google Scholar]
  12. Network ARDS, Brower RG, Matthay MA, et al. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342(18):1301–1308. doi: 10.1056/NEJM200005043421801. [PubMed] [CrossRef] [Google Scholar]
  13. Power JS. U.S. Patent No. 5,673,689. Washington, DC: U.S. Patent and Trademark Office; 1997. [Google Scholar]
  14. Power JS, O'mahony JJ, Merrick EB. U.S. Patent No. 5,531,221. Washington, DC: U.S. Patent and Trademark Office; 1996. [Google Scholar]
  15. Retamal J, Libuy J, Jiménez M, et al. Preliminary study of ventilation with 4 ml/kg tidal volume in acute respiratory distress syndrome: feasibility and effects on cyclic recruitment—derecruitment and hyperinflation. Crit Care. 2013;17(1):R16. doi: 10.1186/cc12487. [PMC free article] [PubMed] [CrossRef] [Google Scholar]
  16. Tobia RL. U.S. Patent No. 5,651,360. Washington, DC: U.S. Patent and Trademark Office; 1997. [Google Scholar]
  17. Waldron KJ, Kinzel GL, Agrawal SK. Kinematics, dynamics, and design of machinery hardcover. 3. United States: John Wiley & Sons Inc; 2016. [Google Scholar]
  18. WebMD, coedited by William CS, Melissa CS (2008) Webster’s new world™ medical dictionary, 3rd edn. Wiley Publishing, Inc., Hoboken, New Jersey.